Bedrijfskritische workloads en gevirtualiseerde omgevingen vereisen compacte en krachtige rekencapaciteit. Precies daarvoor is de HPE ProLiant DL560 Gen9-server ontworpen. Om prestaties, schaalbaarheid en uitbreidbaarheid te leveren in een dichte 2U-voetafdruk.
Implementeer de ideale high-density server met vier sockets voor multi-workload computing met de nieuwste technologie. Het is ontworpen om u te helpen betere prestaties te bereiken tegen de juiste prijs.
Wat is er nieuw
Processor |
One, Two or Four of the following depending on the server model configuration chosen Model, CPU, frequency, Cores, L3 Cache, Power, QPI, DDR4 Hz |
Cache Memory |
One of the following depending on model 55MB (1 x 55MB) Level 3 cache With the E5-4669v4 processor. |
Chipset | Intel® C610 Series Chipset Intel® Xeon® E5-4600v4 Processor Family Intel® Xeon® E5-4600v3 Processor Family |
Memory |
One of the following depending on model Type: |
Memory Protection | Advanced ECC: Advanced ECC uses single device data correction to detect and correct single and all multibit error that occurs within a single DRAM chip. Online Spare Memory: online spare mode detects a rank that is degrading and switches operation to the spare rank. Mirroring mode: Memory mirroring inter-socket stores a copy of memory with dynamic failover in case of failure. Once a DIMM in a mirrored set is detected as failed, the mirror failover uses its mirrored DIMM. Demand and Patrol Scrubbing: Memory demand and patrol scrubbing prevent accumulation of correctable errors and reduces the likelihood of unplanned downtime. Failed DIMM Isolation: Failed DIMM isolation improves the service time thus improving the overall system availability. Data Bus ECC Protection: Data Bus ECC protection provides automatic correction from a single data bit error and detection of double data error bits. Often called single error correction/double error detection (SEC/DED). Memory Thermal Control: Memory thermal control is used to prevent DIMMs from overheating. Achieved by slowing down the memory access rate per the temperature monitored by DIMM sensor. Memory Mirroring Inter-Socket: Memory mirroring inter-socket stores a copy of memory with dynamic failover in case of failure. Once a DIMM in a mirrored set is detected as failed, the mirror failover uses its mirrored DIMM. |
Network Controller |
The HPE ProLiant DL560 Gen9 servers offer a flexible network technology - FlexibleLOMs, which offers customers a choice of 1Gb, 10Gb, or 10Gb base-T Ethernet or converged networking in their embedded adapter. A range of NIC cards are also available to enhance networking capabilities. Entry Model: HPE Ethernet 1Gb 4-port 331FLR Adapter |
Storage Controller |
One of the following depending on model Entry Models: HPE Dynamic Smart Array B140i Controller The P440ar Flexible Smart Array controller is in the Adaptive RAID on Chip slot, enables SAS drives and has 2GB Flash Backed Write Cache for data retention. Performance Models: HPE Smart Array P840/4G Controller The P840 Flexible Smart Array controller enables SAS drives and has 4GB Flash Backed Write Cache for enhanced data retention. |
Internal Storage Devices |
One of the following depending on model Hard Drives: None ship standard |
Maximum Internal Storage | TYPE, CAPACITY, CONFIGURATION Hot Plug SFF SATA 48TB 24 x 2TB Hot Plug SFF SAS 48TB 24 x 2TB Hot Plug SFF SATA SSD 92TB 24 x 3.84TB Hot Plug SFF SAS SSD 92TB 24 x 3.84TB |
Power Supply |
One of the following depending on model: HPE 1200W Common Slot Platinum Hot Plug Power Supply |
Common Slot Power Supplies | One of the following depending on power requirements: HPE 1500W Common Slot Platinum Plus Hot Plug Power Supply HPE 1500W Common Slot 48VDC Hot Plug Power Supply HPE 1200W Common Slot Platinum Plus Hot Plug Power Supply HPE 1200W Common Slot Platinum Hot Plug Power Supply |
System Fans | 6 Hot Plug Fans (with N+1 redundancy) |
Upgradeability | Upgradeable to 4 processors Up to 48 DIMM slots 7 PCIe 3.0 I/0 slots Embedded 10-Port SATA, B140i as standard HPE Flexible Smart Array, Smart Array or Smart HBA Controllers FlexibleLOM slot for 1GbE or 10GbE or QDR/FDR InfiniBand Networking Options Up to 24 SFF drives; or 18 SFF drives with optional Universal Media Bay Optional System Insight Display Redundant Power Supplies |